Operation in TEACHING mode
The teaching procedure differs between for OK product only and for OK/NG
products. (Type of teaching is selectable in CONFGURATION mode.)
The number in < > in the table below represents the button number of the o
unit (see the figure on the right).
TEACH: OK (teaching for OK products only)
In INSPECTION (or RUN)
mode
If you change to RUN mode before teaching for NG product, the ALARM signal is output. The
ALARM signal is held ON until teaching for OK and NG products are successfully completed. As
long as the unit keeps outputting the ALARM signal, it cannot execute an inspection properly.
In TEACHING mode ("TEACH" is displayed.)
Upper line- Binary level: 0 – 255
(default: 150)
<3>: Decreases the value
<4>: Increases the value
Lower line-Exposure time: 0.03 to
50.00 ms (default: 1.93)
<7>: Shortens the exposure time
<8>: Extends the exposure time
If you want to perform a teaching at this
point, press <6> first and then <1>.
SIZE: Resizes the inspection area
If you want to execute a teaching at this
point, press <6> first and then <1> after
resizing.
MOVE: Moves inspection area
<6> : Executes a teaching for the
current product type
Teaching for the current product type is
executed.
DONE: Indicates successful
completion of teaching
FAIL: Abnormal termination of
teaching (the ALARM signal is output.)
<5>: Returns to the top.
peration
You can always
switch the product
types by pressing
<2> and <5> buttons
at the same time.