Panasonic LightPix AE20 User Manual page 43

Table of Contents

Advertisement

ST.NO: (1 to 31)
Station Number function:
Sets a device number (unit) used
for RS-232C communication
BAUD.R: (9.6 to 57.6 kbps)
Baud Rate function:
Sets RS-232C communication
speed
OUT.D: (0 to 160 ms) in the 20 ms
Output Delay function:
Outputs inspection results after the
original output timing
CAP.D: (0 to 160 ms) in the 1 ms
unit
Capture Delay function:
Sets the time delay from TRIGGER
signal input to image capture
I.TRR: (ON / OFF)
Internal Trigger function:
INI.T: (1 ~ 7)
Initial Type:
The selected product type number
when the LightPixAE20 is turned on
(available only for colored areas)
SPEED: High / Middle / Low
Speed:
Allows you to select the processing
time of measurement (available
Color Judgement only)
VER
Version:
Version, size of view range and
system and operation unit versions.
(Size of view range differs
depending on the product number.)
T.TRG: (ON / OFF)
Teaching Trigger function:
Sets external trigger to ON (valid) or
OFF (invalid)
A.BACK: (ON / OFF)
Answer back function:
Displays the detection position in
blue on the finder unit.
36
Color Area
Color Judgement
When the function is set to ON, the
LightPixAE20 automatically performs
continuous inspections
When OFF, inspection is performed
when TRIGGER signal is input.

Advertisement

Table of Contents
loading

Table of Contents