4.5.6 Inspection Execution

The ways of inspection execution
Internal trigger: ON
Internal trigger: OFF
Inspection judgement results
Judgement results are output to the parallel ports of OUT1 to OUT3 as the table shown below.
Judgement results
Point was detected, and the detected peak distance is
OK
within the "base distance +/- allowable range.
NG Except those above
Checking the measured data
When executing an inspection in RUN mode, you can check the X- and Y- directional distance of the
detected edge. But you cannot display all the measurement data at the same time.
Display
data
switch
To the Top
Product
type
switch
*Data range
Type
ANE2000
Data
X
0 to 2.00
Y
0 to 1.60
*The view range changes within the range of 70 x 56 to 100 x 80 depending on the installation position of
ANE2030, but the position data are converted into mm based on the range of view 80 x 70. Therefore, if you use
the unit out of the view range 80 x 70, the position data differs from the actual size.
Parallel input/output timing chart: Page 102
80
Inspection is automatically performed by switching to RUN mode.
After switching to RUN mode, input the TRIGGER signal to external devices or
press the TRIGGER button.
Upper line: Product type number and type of data
Data type: X / Y / TIME
X: X-directional distance of the detected point
Y: Y-directional distance of the detected point
TIME: Calculation time
Lower line: Data value
X-/Y-directional distance: Up to four digits* including
the numbers under the decimal point
(The digits under the decimal point differs depending
on the type of device.)
When any point is not detected, the screen display is
as the figure shown right.
Calculation time: Less than two digits
, slightly differs depending on the position of the
detected point
ANE2010
ANE2020
0 to 10.00
0 to 30.00
0 to 8.00
0 to 25.00
OUT3
OUT2
OUT1
ON
OFF
OFF
OFF
OFF
OFF
The <3>, <4> and <5> buttons:
Changes the product types
Once the product types are
switched,OUT1 to 3 are reset.
ANE2030*
0 to 80.00
0 to 70.00

Advertisement