Panasonic LightPix AE20 User Manual page 104

Table of Contents

Advertisement

Item
V.IMG1 ~ 8:
V.Image1 ~ 8
SV.IMG: OFF / ALL /
NG
Save Image
DIRC.T: Both / DX /
DY
Direction Type
OUT.T: Black / White
Selects a color of
inspection object
VER
Version:
Application version
and type, operation
unit version, system
version and size of
view range
Description
Displays the saved images (up to eight) and the inspection data. If no
image is saved, "EMPTY" is displayed on the operation unit. If any
images are saved, the meaured data are displayed on the operation unit
Example display: Color Area
If no image is saved, "ENPTY" is displayed. If any images are saved, the
number of saved images (detection data) is displayed.
Erasing images
The saved images are removed when the main unit was turned
off. You can also delete them by using AETOOL.
Saving images on PC
Using the software for the LightPixAE20 (AETOOL) saves the
saved images in a bitmap form on PC. Refer to AETOOL help file
for more details.
*When switching the image numbers, hold down the <7> and <8>
buttons.
Automatically saves the inspected images. Sets whether or not any
images are save or when the images are saved.
OFF: Saves no image
ALL: Saves the last captured images (up to eight)
NG: Saves the last images judged as NG (up to eight)
Allows you to select a direction in which lengths are measured
Both: Lengths are measured in both X and Y directions
DX: Lengths are measured only in the X (horizontal) direction
DY: Lengths are measured only in the Y (vertical) direction
Allows you to select a color (black or white) of the part for measurement.
Measurement is executed using a binary image, so you have to decide a
pixel color (black or white) of the pixels to inspect after binarizing the
captured image
Application, operation unit, system version and view range
About each version
n.nn:NN =
n.nn: Version for the current application
NN: Indicates the type of application
00: Color Area, 01 = Color Judgement, 02 = Color Pattern
Matching, 03= Edge
04: Peak, 05 = Measurement
n.nn:OP = Indicates the operation unit version
n.nn:SY = Indicates the system version
Size of view range: Differs depending on the product number
ANE2000: 2. 1.6
ANE2010: 10. 8
ANE2020: 30. 25
ANE2030: 80. 70
("80.70" is displayed, but actual size of view range differs
depending on the installation distance. Size of view range 70: 56
– (installation distance: 140) – 100.80 (installation distance: 220)
Applica-
tion
All
All
Measurem
ent
Measurem
ent
All
97

Advertisement

Table of Contents
loading

Table of Contents