4.6.4 Setting a Minimum Value for a Mesurement Object

In JUDGEMENT CRITERIA SETTING and MESUREMENT OBJECT MIN. SETTING mode, set the length of
an inspection object.
You can set up to four digits including the numbers under the decimal point, but the
number of digits you can set varies depending on the type of unit.
The number in < > in the table below represents the button number of the operation
unit (see the figure on the right).
In INSPECTION (or RUN) mode
JUDGEMTENT CRITERIA/MEASUREMENTOBJECT MIN.
SETTING mode ("SET" is displayed.)
Referring the value saved when executing a teaching
Allowable range to be set
PMinX: Min. in the X direction
PMaxX: Max. in the X direction
PMinY: Min. in the Y direction
PMaxY: Max. in the Y direction
MinX: Min. for Measurement Object – in the X
direction
MinY: Min. for Measurement Object-in the Y
direction
Product type
No.2
RMinX: Min. in the X direction
RMaxX: Max. in the X direction
RMinY: Min. in the Y direction
RMaxY: Max. in the Y direction
The <8> button: Increases the value
The <7> button: Decreases the value
The <8> button: Increases the value
The <7> button: Decreases the value
The <8> button: Increases the value
The <7> button: Decreases the value