Operation in TEACHING mode
Operation in TEACHING mode differ the type of teaching (the type of teaching is
settable in CONFIGURATION mode.
The number in < > in the table below represents the button number of the o
unit (see the figure on the right).
TEACH: OK (teaching for OK product only)
In INSPECTION (or RUN)
mode
The ALARM signal is held on until teaching is successfully completed. As long as the unit keeps
outputting the ALARM signal, it cannot execute an inspection properly.
76
TEACHING mode ("TEACH" is displayed.)
Upper line
Binary level: 0 – 255 (default: 150)
<3>: Decreases the value
<4>: Increases the value
Lower line
Exposure time: 0.03 - 50.00 ms
(default: 1.93)
<7>: Shorten the exposure time
<8>: Longer the exposure time
If you want to perform a teaching at
this point, press <6> first and then
<1>
SIZE: Resizes the inspection area
If you want to perform a teaching at
this point, press <6> first and <1>.
MOVE: Moves the inspection area
<6>: Executes a teaching
Executes a teaching for OK product
of the current product type
DONE: Indicates successful
completion of teaching
FAIL: Abnormal termination of
teaching (the ALARM signal is
output.)
<5>: Returns to the top.
peration
You can always
switch the product
types by pressing
<2> and <5> buttons
at the same time.