TEACH: OKNG (teaching for OK and NG products)
In INSPECTION (or RUN)
mode
If you change to RUN mode before teaching for NG product, the ALARM signal is output. The
ALARM signal is held ON until teaching for OK and NG products are successfully completed. As
long as the unit keeps outputting the ALARM signal, it cannot execute an inspection properly.
In TEACHING mode ("TEACH" is displayed.)
Upper line
Binary level: 0 – 255 (default: 150)
<3>: Decreases the value
<4>: Increases the value
Lower line
Exposure time: 0.03 - 50.00 ms
(default: 1.93)
<7>: Shorten the exposure time
<8>: Longer the exposure time
If you want to perform a teaching at
this point, press <6> first and then
<1>
SIZE: Resizes the inspection area
If you want to perform a teaching at
this point, press <6> first and <1>.
MOVE: Moves the inspection area
<6>: Executes a teaching
Executes a teaching for OK product
of the current product type
STNG: Teaching for OK
products-Normal completion
FAIL: Abnormal termination of
teaching
→The ALARM signal is output.
<6>: Executes a teaching
Executes a teaching for NG product
of the current product type
DONE: Teaching for
NGproduct-Normal completion
FAIL: Abnormal teaching
(the ALARM signal is output.)
<5>: Returns to the top.
You can always
switch the product
types by pressing <2>
and <5> buttons at the
same time.
77