Function
Display on the operation unit
Upper: Function name and options
(The left LCD display shows default settings.)
to be displayed
Middle: Name
Lower: Description
ST.NO: (1 ~ 31)
Station Number function:
Sets a device number (unit) used
for RS-232C communication
BAUD.R: (9.6 ~ 57.6 kbps)
Baud Rate function:
Sets RS-232C communication
speed
OUT.D: (0 to 160 ms) in the 20 ms
Output Delay function:
Outputs inspection results after the
original output timing
CAP.D: (0 to 160 ms) in the 1 ms
unit
Capture Delay function:
Sets the time delay from TRIGGER
signal input to image capture
I.TRR: (ON / OFF)
Internal Trigger function:
When the function is set to ON, the
LightPixAE20 automatically
performs continuous inspections.
When OFF, it performs an
inspection every time trigger signal
input.
INI.T: (1 ~ 7)
Initial Type:
The selected product type number
when the LightPixAE20 is turned on
(available only for colored areas)
SPEED: (High / Mid / Low)
Speed
High: High speed, low resolution
Low: Low speed, high resolution
VER
Version:
Version, size of view range and
system and operation unit versions.
(size of view range differs
depending on the product number.)
50