4
5) Removal of the pressure roller/roller bearings
12
3
1
2
(4)Remove the springs.
(5)Turn the separation fingers and remove
them.
4
SV506
• Remove the heat roller (refer to step 5 to
7).
• Remove the upper / lower separation
finger brackets (refer to 10 and 11).
Note: Mark the current height adjustment to
use as a reference during re-
assembly.
1
(1)Remove the screws (x 2).
(2)Remove the entry guide.
(3)Remove the pressure roller.
(4)Remove the roller bearing.