Toshiba GRE110 Instruction Manual page 194

Overcurrent protection relay
Table of Contents

Advertisement

No. LCD indication
89
SEF1 block
90
SEF2 block
91
SEF3 block
92
SEF4 block
93
UC block
94
THM block
95
NPS block
96
BCD block
97
TC fail
98
CB CONT OPN
99
CB CONT CLS
100 EXT trip-3PH
101 EXT trip-APH
102 EXT trip-BPH
103 EXT trip-CPH
104 Remote reset
105 Store record
106 Alarm1
107 Alarm2
108 Alarm3
109 Alarm4
110 Relay fail
111 Relay fail-A
112 TC err
113 CB err
114 CT err
115 TP COUNT ALM
116 ΣI^yA ALM
117 ΣI^yB ALM
118 ΣI^yC ALM
119 OP time ALM
120 F.record CLR
121 E.record CLR
122 D.record CLR
123 TP COUNT
124 ΣI^y CLR
125 Max.DEM CLR
126 IND.reset
127 Data lost
128 Sys.Set
129 Rly.Set
130 Grp.Set
131 OC1-A INST
132 OC1-B INST
133 OC1-C INST
Contents
Off / On
BI command of SEF1 protection scheme block
Off / On
BI command of SEF2 protection scheme block
Off / On
BI command of SEF3 protection scheme block
Off / On
BI command of SEF4 protection scheme block
Off / On
BI command of UC protection scheme block
Off / On
BI command of THM protection scheme block
Off / On
BI command of NPS protection scheme block
Off / On
BI command of BCD protection scheme block
Off / On
BI command of Trip circuit Fail Alarm
Off / On
BI command of CB N/O contact
Off / On
BI command of CB N/C contact
Off / On
BI command of External trip (3 Phase)
Off / On
BI command of External trip (A Phase)
Off / On
BI command of External trip (B Phase)
Off / On
BI command of External trip (C Phase)
Off / On
BI command of Remote reset
Off / On
BI command of Store Disturbance Record
Off / On
BI command of Alarm1
Off / On
BI command of Alarm2
Off / On
BI command of Alarm3
Off / On
BI command of Alarm4
Off / On
Relay failure & trip blocked alarm
Off / On
Relay failure alarm (Trip not blocked)
Off / On
Trip circuit supervision failure
Off / On
Circuit breaker status monitoring failure
Off / On
CT circuit supervision failure
Off / On
Trip counter alarm
ΣIY A-Phase alarm
Off / On
ΣIY B-Phase alarm
Off / On
ΣIY C-Phase alarm
Off / On
Off / On
Operate time alarm
On
Clear Fault records
On
Clear Event records
On
Clear Disturbance records
On
Clear Trip counter
Clear ΣIY counter
On
On
Clear Max. demand (Imax)
On
Reset the indication of Trip mode, Alarm etc.
Record and time data lost by power supply off
On
for a long time
On
System setting change command
On
Relay setting change command
On
Group setting change command
Off / On
OC1-A relay element start
Off / On
OC1-B relay element start
Off / On
OC1-C relay element start
 195 