Blue Screen Error Status Screen - Siemens SINUMERIK 840D Operator's Manual

Computerized numerical control system for machine tools
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

2
03.04
Restrictions:

2.5.12 Blue screen error status screen

 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/810D Operator's Guide HMI Embedded (BEM) – 03.04 Edition
2.5 General operating sequences
Note
Angle specifications are not supported.
Example:
F20H7
or:
F20h7
or:
F
= fit
20
= Diameter/length specification (1... 500 mm)
H (h)
= tolerance class (tolerance classes for drill holes and shafts:
7
= Tolerance quality identifier (01... 18, DIN standard 7150
1. The diameter/length must be specified as an integer.
2. Quality identifiers 6, 7, 8 are available for class J.
3. For class j, only qualities 5, 6, 7 and 8 are available for diameter
1...3 mm.
4. Only qualities 8...18 are available for classes P, R, S; T, U, V, X,
Y, Z, ZA, ZB, ZC, p, r, s, t, u, v, x, y, z, za, zb, zc.
5. Qualities CD, EF, FG, cd, ef, fg are only available for up to
10 mm.
6. According to the standard,
classes T, t are only available for diameters > 24 mm,
classes T, t are only available for diameters > 14 mm,
classes Y, y are only available for diameters > 18 mm,
Recompilation of the value is not possible.
Upper/lowercase notation:
The operator panel does not have separate keys for lowercase letters,
but you can use the selection key to change between upper and
lowercase notation.
Position the cursor on a letter in the input field and press the selection
key to toggle between upper and lowercase notation.
When you have finished, press the ENTER key to confirm your input.
In the event of a system crash, an error status screen displays the
current system information. The screen shows a brief description of
the error and displays any relevant process registers.
You will find various options for saving system information in the
following documentation:
References: /IAM/ Installation & Start-Up Guide HMI Embedded
(IM2)
Operator Components/Operating Sequences
This input stands for 20H7
This input stands for 20H7
A, B, C, D, E, F, G, H, J, JS, T, U, V, X, Y,
Z, ZA, ZB, ZC)
limits the area!)
2
2-63

Advertisement

Table of Contents
loading