NEC UNIVERGE SV8100 Features & Specifications Manual page 822

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
PINX
This is the remote system to which the QSIG connection is connected.
Configuration
QSIG connection set as QT on originating system
If the QSIG connection is intended to be set as QT the following would require to be configured:
Calls from QT to PINX
F-route is required to be configured to route calls from the Originating System to the PINX See F-route
section.
Calls from PINX to QT
In order to route calls from the PINX to the Originating System via a QT interface it is necessary to
configure DDI routing for the QT channels.
Breakout calls from Originating System
It is not possible for calls from the PINX to break out onto PSTN trunks on the originating system.
QSIG connection set as QS on originating system
If the QSIG connection is intended to be set as QS the following would require to be configured:
Calls from QS to PINX
The B-channels of the QS connection are required to be configured as a department group to route calls
from the Originating System to the PINX.
E.g. if extensions on PINX are 3xx the following example could be employed.
1.
16-02-01 - set QS B-channels to department group
2.
11-01-01 - dial 3 digit 1 Type 2
3.
11-07-01 - set department group pilot number from step 1 to 3
4.
10-03-07 - set additional digits to 2
See Department group section.
Calls from PINX to QS
No additional configuration should be required for this connection.
Breakout calls from Originating System
No additional configuration should be required for the PINX to break out onto PSTN trunks on the
originating system.
Breakout calls from Originating System to PINX
It is not possible to breakout from the PINX if QS is configured as additional dialling is not possible.
1 - 812