NEC UNIVERGE SV8100 Features & Specifications Manual page 764

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
Program
Number
80-03-05
80-03-06
80-03-07
80-03-08
80-04-04
1 - 754
Program Name
DTMF Tone Receiver Setup –
Forward Twist Level
DTMF Tone Receiver Setup –
Backwards Twist Level
DTMF Tone Receiver Setup – ON
Detect Time
DTMF Tone Receiver Setup –
OFF Detect Time
Call Progress Tone Detector
Setup – No Tone Time
Description/Comments
Use this option to define the
forward twist level for DTMF Tone
Receiver.
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
Use this option to define the On
detection time for DTMF Tone
Receiver.
Use this option to define the Off
detection time for DTMF Tone
Receiver.
Use to define the no tone time for
the Call Progress Tone Detector.
(OPX) Off-Premise Extension
UNIVERGE SV8100
Assigned Data
0~9
(1dB ~ 10dB)
default:
Type 1 = 5 (6dBm)
Type 2 = 5 (6dBm)
Type 3 = 5 (6dBm)
Type 4 = 5 (6dBm)
Type 5 = 5 (6dBm)
0~9
(1dB ~ 10dB)
default:
Type 1 = 0 (1dBm)
Type 2 = 0 (1dBm)
Type 3 = 0 (1dBm)
Type 4 = 0 (1dBm)
Type 5 = 0 (1dBm)
1~255
(15+ 15 ms ~ 3825 ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
1~255
(15+ 15 ms ~ 3825 ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents