Philips LPC2119 User Manual page 239

Arm-based microcontroller
Hide thumbs Also See for LPC2119:
Table of Contents

Advertisement

Philips Semiconductors
ARM-based Microcontroller
Blank check sector(s) <start sector number> <end sector number>
Table 208: ISP Blank check sector(s) command description
Command
Input
Return Code
Description
Example
Read Part ID
Table 209: ISP Read Part ID command description
Command
Input
Return Code
Description
Example
Read Boot code version
Table 210: ISP Read Boot Code version command description
Command
Input
Return Code
Description
Example
Flash Memory System and Programming
I
Start Sector Number
End Sector Number: Should be greater than or equal to start sector number.
CMD_SUCCESS |
SECTOR_NOT_BLANK (followed by <Offset of the first non blank word location> <Contents of non
blank word location>) |
INVALID_SECTOR |
PARAM_ERROR
This command is used to blank check a sector or multiple sectors of on-chip Flash memory. To blank
check a single sector use the same "Start" and "End" sector numbers.
"I 2 3<CR><LF>" blank checks the flash sectors 2 and 3. Blank check on sector 0 always fails as
first 64 bytes are re-mapped to flash boot sector.
J
None
CMD_SUCCESS followed by part identification number in ASCII format.
This command is used to read the part identification number.
"J<CR><LF>".
K
None
CMD_SUCCESS followed by 2 bytes of boot code version number in ASCII format. It is to be
interpreted as <byte1(Major)>.<byte0(Minor)>
This command is used to read the boot code version number.
"K<CR><LF>".
LPC2119/2129/2292/2294
239
Preliminary User Manual
January 08, 2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpc2129Lpc2292Lpc2294

Table of Contents