Set Power Blade Poweroff Order - Hitachi Compute Blade 500 Series User Manual

Cli console user's guide
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Comment
Power supply module optimization can not be enabled when the chassis is in
silent mode.

set power blade poweroff order

Command
set power blade poweroff order -o <blade_off_order> [-F]
Description
Sets the order of server blades to power off when the power consumption
exceeds the power capacity. When setting the order with this command,
specify all server blade slot numbers 0 to 7.
In SMP configuration, server blades turn off in the order specified on the
primary server blade. Although the order specified on a non-primary server
blade will not affect the operation, specify all server blade slot numbers using
-o parameter.
Role
Chassis
Parameters
-o <blade_off_order>
Order of server blades to power off when the power consumption
exceeded the power capacity
-F
Executes the command without inquiry.
Show items
None
Message
None
Example
[Sets the order for server blade 7,6,5,4,3,2,1,0]
$ set power blade poweroff order -o 7,6,5,4,3,2,1,0 -F
I0001 : Setting was completed.
S0002 : Command succeeded.
2-204
Specify slot numbers of server blade in priority order and separate by
comma. Range is from 1 to 8 avoiding duplicates.
CLI command
Hitachi Compute Blade 500 Series CLI Console User's Guide