Hitachi Compute Blade 500 Series User Manual page 75

Cli console user's guide
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Parameters
<blade_no>
Slot number of the server blade in the server chassis
Range is from 0 to 7.
Multiple selection is available.
If 'all' is specified for this parameter or this parameter is omitted, the
command shows all server blades.
-h
Restart the BMC with power off and on sub power.
If omitted -h, -s, and -sb parameter, this parameter is applied.
-s
Restart the BMC. In SMP configuration, BMC is restarted on all server
blades.
-sb
Restart BMC only on a specified server blade. In SMP configuration, BMC
is restarted only on the specified primary server blade and non-primary
server blade.
-F
Executes the command without inquiry.
Show items
None
Message
None
Example
[The sub power supply of the server blade 0 is turned off / on.]
$ bmc-reset blade 0
Confirm? (y/[n]):y
I0033 : <Blade 0> Restart was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
[BMC of all the server blades are rebooted.]
$ bmc-reset blade all -s
Confirm? (y/[n]):y
I0033 : <Blade 0> Restart was completed.
I0033 : <Blade 1> Restart was completed.
I0033 : <Blade 2> Restart was completed.
I0033 : <Blade 3> Restart was completed.
I0033 : <Blade 4> Restart was completed.
I0033 : <Blade 5> Restart was completed.