I0107 : <Blade 0> Update firmware was started.
I0042 : <Blade 0> Update firmware was completed.
I0015 : Update firmware was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
[Updates firmware of server blade 0 and 2 that compose SMP configuration.]
$ update blade firmware bulk 0,2 -f xxx.update
W0012 : BMC restart automatically.
W0013 : New EFI firmware will be used the next time EFI is
booted.
Confirm? (y/[n]):y
I0107 : <Blade 0> Update firmware was started.
I0107 : <Blade 2> Update firmware was started.
I0042 : <Blade 0> Update firmware was completed.
I0042 : <Blade 2> Update firmware was completed.
I0015 : Update firmware was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
Comment
Send the firmware update file with FTP protocol before executing this
command. If you send the firmware update file during firmware update using
this command, the update may fail. If it fails, execute the update again.
If you do not specify all server blades in SMP configuration, the following
message appears without updating firmware.
E0655 : <Blade X> Command was canceled. Only a part of the blades of the
SMP is specified. (X: a server blade you specified)

set blade ac-recovery

Command
set blade ac-recovery [<blade_no>] [-a <ac_recovery>] [-w
<wait_time>] [-F]
Description
Edits behavior of server blade when the AC power is recovered to the server
chassis.
In SMP configuration, when you specify the primary server blade, AC-
recovery setting for all server blades in the configuration is changed. When
CLI command