Create MyConfig - Expert
4.12 Command line call
Switch
Arguments
/config
(<"Path configuration
file>")
/protect
-
/log
(<"Path log file>")
The replacements of the switches, valid up to version V4.6, are listed in the following table.
Table 4-39
Replacement of the switches (valid up to version V4.6)
Switches valid up to version V4.6
/pack <Project file path>
/deploy <" Deployment name">
/deploydir <"Deployment directo‐
ry">
/target< NCU | PCU | UAZ >
/uss <"uss file path">
/ust <"ust file path">
/tgz <"tgz file path">
/sdb <"sdb file path">
/utz <"utz file path">
Return values
Note
The return values for the Expert command line call only apply if Expert is executed in /silent
mode without the user interface.
336
Optional
Description
Yes
The switch means that after calling Expert after opening the project,
the configuration file (*.upcfg) is processed.
In addition to the defined system variables, system variables that are
equivalent to the out-of-date switches can be included in this config‐
uration file.
See the following table, "Replacing switches (valid up to version
V4.6)"
Note
Configuration files (*.upcfg) can be exported and saved via Expert.
Yes
Reimport protection can be set, so that packages deployed can no
longer be reimported using Expert.
Yes
Alarms and faults are written to the log file (XML format) when check‐
ing and deploying the package.
If the argument is not specified, the log file with the name of the pack‐
age in the current work folder (where batch or CMD were called) is
automatically generated.
Replacement by system variables (valid from version V4.7)
Path of the project file after calling expert.exe
Example: expert.exe D:\Projects\MyProject.upz
Up.$Pack.DeployName="Deployment name"
Up.$Pack.DeployDir="Deployment directory"
Up.$Pack.DeployTarget=Up.$Pack.DeployTargets.LINUX
Up.$Dialog.StepSelection.CfgFile="Path of the uss file"
Up.$Dialog.DriveTopology.UstFile="Path of the ust file"
Up.$Dialog.NcuSetup.TgzFile="Path of the tgz file"
Up.$Dialog.SystemConfig.SdbFile="Path of the sdb file"
Up.$Dialog.DriveTopology.UtzFile="Path of the utz file"
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo