System Configuration (Package Execution) - Siemens SINUMERIK 840D sl Operating Manual

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Setting disabled
Yes
No
Preselection of the offline archive
Dialog scripts
Under "Dialog scripts", entry "Scripts", via the button
configuration' Edit event scripts". Here you can edit scripts that are to be executed at selectable
times during package processing.
You can find detailed information on the dialog scripts in the section with the same name
"Dialog scripts (Page 115)".
You can find an example for the dialog scripts for the system configuration in "Examples of
scripts in dialog pages (Page 119)".
4.4.2.25

System configuration (package execution)

If the "System configuration" dialog page is executed in editing mode "Manual", the "Origin of
data" can be adapted for every area if the project engineer has not locked this.
In the case of "Offline archive", archives must be selected that were either transferred with the
package, are located next to the package (prefix "./") or are inserted at any location using the
("Search") button.
Note
If, during package execution, a jump is made to the System configuration dialog page via
"Back", then the archives backed up there are reused, and changes that have possibly already
been made are rejected.
Example
Example: Archive next to the package:
./myPath/myArchive.arc
A "myArchive.arc" archive from the "myPath" folder, which is located next to the package, is
used.
The "./" prefix stands for the current path in which the package file is located at the time of
execution.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
The selection at "Source of the data" can be blocked by the project engineer
via this option in order to prevent changes by the operator during the package
execution.
Under "Preselection of the offline archive", a SINUMERIK archive can be inser‐
ted, linked or preselected from the list.
Alternatively, enter the path of a file which is located next to the package /
<Path>/<File>,
e.g. "./DRV-data.arc".
Note
When data for "Offline Archive" is entered in the step tree via components, an
archive from the overall reset state must be saved here or the "Origin of the
data" must be set to "Overall reset".
Create MyConfig - Expert
4.4 Project folder
you open the "Dialog 'System
165