Module Catalog - Siemens SINUMERIK 840D sl Operating Manual

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Topo
6.4 Topo - operation
Additional functions
In addition to the standard functions such as "Cut", "Copy", "Paste", etc., the context menu of
the topology configurator provides further functions:
Function
Edit
Replace component
Convert Component
Rewire
Search
Print
Zoom
See also
Module catalog (Page 366)
Topo - menu functions (Page 360)
6.4.2

Module catalog

Modules
As of the CMC software version V4.7, the new module catalog replaces the display of the
module window. The modules are saved with article numbers and a brief description. It is
possible to insert the components specifically or unspecifically. Inserting is implemented by
means of drag and drop or directly in the topology.
366
Description
If a topology has been read in via an archive, it will be displayed write-protected on a gray
background.
By editing or by clicking on the Import button, it is included in the topology list and can be
processed.
Replaces an already connected component with an equivalent component from a different
topology of the opened topology project. Only components from the same device class and
that have the same number of DRIVE-CLiQ ports are listed. When replacing components, all
of the components wired to the original component are kept.
Converts the selected component and directly connected lower-level components into an‐
other module.
SMI, SMC and DQE modules can be converted in this way.
Downlink port:
In Topo, a component is always generally wired to the lower-level component with its first
DRIVE-CLiQ port (X100, X200, ...). If the wiring is to be made to another port, then any free
DRIVE-CLiQ port can be selected here.
Uplink port:.
In Topo, as a standard, a component is always wired to the higher-level component using its
first DRIVE-CLiQ port (X100, X200, etc.). If the wiring is to be made to another port, then any
free DRIVE-CLiQ port can be selected here. Rewiring is also possible by means of drag-and-
drop
Lets you search for character strings within the topology tree.
Allows a topology tree or a topology graph to be printed out. For a topology graph, in addition,
a legend of all properties can also be printed out at the same time.
Only in the topology graph
Allows the size of the display to either be increased or decreased (zoom in/zoom out) in the
topology graph. The size can also be changed as required by holding down "Ctrl" and turning
the mouse wheel.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo