Figure 6-22
Automatically created DOs for DRIVE-CLiQ components
SINAMICS automatically creates DOs for specific DRIVE-CLiQ components.
Automatically created DOs for DRIVE-CLiQ components:
control_unit_ncu,
motor_module_hf control_unit_nx, control_unit_cu, line_module, motor_module, hub_module,
terminal_module,
terminal_board.
SINAMICS components for which a DO is created, can be assigned a "dovar" attribute. Using
the "dovar" attribute, the component is assigned a DO variable. This DO variable contains the
properties of the DO that can be used subsequently by the package when executing the
package.
If such a component was assigned a DO variable manually or via the Topo XML file, this DO
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
DRIVE-CLiQ connection type
Analog connection type
Power connection type
S120 Combi topological modeling
Create MyConfig - Topo
6.9 Interface Topo XML
403