Siemens SINUMERIK 840D sl Operating Manual page 382

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Topo
6.6 SINAMICS device configuration
Automatic configuration
The step-by-step commissioning is possible only to a limited
extent (e.g. the addition of DQI/SMI motors).
The specification of the comparison topology file allows the
DRIVE-CLiQ wiring to be checked.
Configuration in Expert
When configuring in Expert, on the "System configuration" dialog page in section "DRV..."
under "Origin of data", you can define which of the four applications "Initial state,"
"Automatic configuration," "User-specified topology," or "Offline archive" is applicable.
When you select the "User-specified topology" mode, it is imperative to generate a file with
the user-specified topology with Topo and to make it available to the package for execution
on the "SINAMICS topology" dialog page. The user-specified topology file has a binary format
with the file extension *.utz.
If "Automatic configuration" is performed, you can optionally use a file containing the
comparison topology in XML format and with the file extension *.ust or xml on the "SINAMICS
topology" dialog page. This is used for comparison with the automatically detected topology.
The two topology files can be configured in one package. During execution, the "Origin of data"
setting under "DRV archive data/drive configuration" on the "System configuration" page
determines which of the two settings will be used on the following "SINAMICS topology" page.
Both the user-specified topology and the comparison topology contain the topology of the
SINAMICS and other properties of the DOs and the components.
Figure 6-8
CMC package structure
382
User-specified topology
The step-by-step commissioning is possible almost without
limitation (e.g. the addition of DQI/SMI motors).
The SINAMICS reports an error if the topology specified in
the user-specified topology cannot be implemented.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents