1A-8 HEATER AND VENTILATION
BLOWER FAN MOTOR
1. Blower fan motor unit
2. Blower fan motor resistor
3. Blower fan motor relay
4. Blower fan
5. Blower fan motor assembly
1. ECM
3. Instrument panel lower member
2. ECM mounting bolt
4. Lower member mounting bolt
ON-VEHICLE SERVICE
REMOVAL
1) Disconnect negative (–) cable at battery.
2) If equipped with air bag system, disable air bag system. Refer
to "Disabling Air Bag System" in SECTION 9J.
3) Remove grove box, ECM and instrument panel lower member.
4) Disconnect blower fan motor and resistor lead wires at cou-
plers.
5) Disconnect fresh air control cable from blower fan motor unit.
6) Remove blower fan motor unit.
INSTALLATION
Reverse removal procedure for installation, and then note the fol-
lowing instruction.
D If equipped with air bag system, enable air bag system. Refer to
"Enabling Air Bag System" in SECTION 9J.