Suzuki SY413 Service Manual page 1457

Table of Contents

Advertisement

G. REFRIGERANT LINES
Inspection
1) Use a leak tester to check hoses and pipes for any gas leakage.
2) Check each hose or pipe clamp for tightness.
Retighten or replace loose clamp as required, if any.
Removal
1) Recover refrigerant by using recovery and recycling equip-
ment. Be sure to follow the instruction manual for the equip-
ment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
2) Replace defective hose or pipe.
NOTE:
As soon as the above hose or pipe is disconnected, cap its
opened fitting to prevent moisture and dust from entering.
Installation
1) Reverse removal procedure to install refrigerant line.
2) Evacuate and charge system according to previously-de-
scribed procedure.
H. ELECTRICAL CIRCUIT
A/C SWITCH
Inspection
Refer to "MODE CONTROL SWITCH" in Section 1A.
AIR CONDITIONING (OPTIONAL) 1B-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sy416Sy418

Table of Contents