Operation
6.3 Basic information about the drive system
Binectors, BI: binector input, BO: Binector output
A binector is a digital (binary) signal without a unit which can assume the value 0 or 1.
Binectors are subdivided into binector inputs (signal sink) and binector outputs (signal
source).
Table 6- 3
Abbreviation and sym-
Connectors, CI: connector input, CO: Connector output
A connector is a digital signal e.g. in 32–bit format. It can be used to emulate words (16 bits),
double words (32 bits) or analog signals. Connectors are subdivided into connector inputs
(signal sink) and connector outputs (signal source).
The options for interconnecting connectors are restricted to ensure that performance is not
adversely affected.
Table 6- 4
Abbreviation and sym-
Interconnecting signals using BICO technology
To interconnect two signals, a BICO input parameter (signal sink) must be assigned to the
desired BICO output parameter (signal source).
198
Binectors
Name
bol
Binector input
Binector Input
(signal sink)
Binector output
Binector output
(signal source)
Connectors
Name
bol
Connector input
Connector input
(signal sink)
Connector output
Connector output
(signal source)
Description
Can be interconnected to a binector output as
source.
The number of the binector output must be en-
tered as a parameter value.
Can be used as a source for a binector input.
Description
Can be interconnected to a connector output as
source.
The number of the connector output must be
entered as a parameter value.
Can be used as a source for a connector input.
Operating Instructions, 07/2016, A5E00331449A