Additional functions
16.6 Check scope of NC language present (STRINGIS)
Meaning
SCPARA
<axis>
<value>
Example
Program code
...
N110 SCPARA[X]= 3
...
Further information
Enable of the parameter set changeover
The parameter set changeover of the axis must be explicitly enabled:
MD35590 $MA_PARAMSET_CHANGE_ENABLE[<axis>]
Read parameter set number
The number of the selected parameter set (specified parameter set) can be read via the
system variable $AA_SCPAR.
References
Detailed information on the parameter sets can be found in:
Function Manual, Basic Functions; Section "Velocities, setpoint / actual value systems,
closed-loop control (G2)" > "Closed-loop control" > "Parameter sets of the position controller"
16.6
Check scope of NC language present (STRINGIS)
Function
Using the function
available as element of the NC programming language in the actual language scope.
Definition
INT STRINGIS(STRING <Name>)
594
:
Command: Change parameter set
:
Axis identifier (channel axis)
Type:
:
Parameter set number: 1, 2, 3, ... max. parameter set number
Comment
; Selection: Axis X, 3rd parameter set
...
STRINGIS(
AXIS
it can be checked as to whether the specified string is
)
Programming Manual, 03/2013, 6FC5398-2BP40-3BA1
Job Planning