Mitsubishi Electric A173UHCPU Programming Manual page 366

Motion controller
Hide thumbs Also See for A173UHCPU:
Table of Contents

Advertisement

APPENDICES
POINTS
(1) All special register data is cleared by the power-off, latch clear, and reset
operations. The data is retained when the RUN/STOP key switch is set to
STOP.
(2) The contents of the special relays marked "Note-1" in the table above are
not cleared even after the normal status is restored. To clear the
contents, use one of the following methods:
(a) Using a user program
Insert the ladder block shown at right into the program and turn on
the clear execution command contact to clear the contents of the
register.
(b) Using a peripheral device
Using the test function of a peripheral device, set the register to "0"
by using current value change or forced reset.
For details on the operation involved, refer to the manual for the
relevant peripheral device.
(c) Set the special register to "0" by setting the RESET key switch on the
front of the CPU to the RESET position.
Clear execution
command
(3) For special registers marked "Note-2", data is written in the sequence
program.
(4) For the special registers marked "Note-3", data are written in the test
mode of the peripheral device.
(5) The special registers marked "Note-4" are cleared only when power is
switched from OFF to ON.
APP − 49
RST
M9005
Enter the number
to be cleared.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A273uhcpu

Table of Contents