Fujitsu Airstage J-II Series Design & Technical Manual page 710

Small vrf system
Table of Contents

Advertisement

LED105
Setting Mode
CODE No.
Energy saving
3
0
level setting
3
2
Prohibited
3
3
Prohibited
Presence of
heater selection
3
5
control using
outdoor
temperature
Outdoor
temperature
zone boundary
3
6
temperature
A
Outdoor
temperature
zone boundary
3
7
temperature
B
*1: Do not set this for outdoor units with Slave setting.
LED104
Setting Function
CODE No.
0
0
Level 1 (stop)
Level 2 (operated at
0
1
40% capacity)
Level 3 (operated at
0
2
60% capacity)
Level 4 (operated at
0
3
80% capacity)
Level 5 (operated at
0
4
100% capacity)
0
0
Prohibited
0
1
Prohibited
0
2
Prohibited
0
0
Prohibited
0
1
Prohibited
0
0
Disable
0
1
Enable
0
0
-4.0°F (-20°C)
0
1
-0.4°F (-18°C)
0
2
3.2°F (-16°C)
0
3
6.8°F (-14°C)
0
4
10.4°F (-12°C)
0
5
14.0°F (-10°C)
0
6
17.6°F (-8°C)
0
7
21.2°F (-6°C)
0
8
24.8°F (-4°C)
0
0
42.8°F (6°C)
0
1
14.0°F (-10°C)
0
2
17.6°F (-8°C)
0
3
21.2°F (-6°C)
0
4
24.8°F (-4°C)
0
5
28.4°F (-2°C)
0
6
32.0°F (0°C)
0
7
35.6°F (2°C)
0
8
39.2°F (4°C)
0
9
42.8°F (6°C)
1
0
46.4°F (8°C)
1
1
50.0°F (10°C)
1
2
53.6°F (12°C)
1
3
57.2°F (14°C)
1
4
60.8°F (16°C)
1
5
64.4°F (18°C)
- (07 - 63) -
Outdoor unit
Factory
setting
Master Slave
l
The capacity limit can be
selected by the external
input terminal (CN133) when
operating with the "Energy
-
Saving Peak Cut function."
¡
*1
The lower the level, the more
the effect of energy saving, but
the cooling/heating performance
will also drop.
l
Setting prohibited
l
Setting prohibited
Setting required to validate
the setting of heater selection
l
control using outdoor
temperature 1 and 2 (setting
-
value: 03 or 04) in field setting
¡
*1
61 (indoor unit) for heater
control switching.
For details, refer to Chapter 8.
1-2-2. EXTERNAL OUTPUT.
l
Setting required if changing
of the outdoor temperature
setting for heat pump prohibition
zone is required when heater
selection control using outdoor
-
¡
temperature 1 and 2 are
*1
performed on the indoor unit.
For details, refer to Chapter 8.
1-2-2. EXTERNAL OUTPUT.
l
Setting required if changing
of the outdoor temperature
setting for heat pump only
zone is required when heater
selection control using outdoor
-
¡
temperature 1 is performed on
*1
the indoor unit.
For details, refer to Chapter 8.
1-2-2. EXTERNAL OUTPUT.
Remarks