Function Details - Fujitsu Airstage J-II Series Design & Technical Manual

Small vrf system
Table of Contents

Advertisement

2-8. FUNCTION DETAILS

Function
Function
number
00
Filter
indicator
11
01
interval
02
00
Filter
01
indicator
13
action
02
00
Ceiling
20
airflow
01
00
Vertical
airflow
23
01
direction
Horizontal
00
swing
01
24
airflow
02
direction
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Static pressure
26
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
00
Cool air tem-
01
30
perature trigger
02
00
01
Heat air tem-
31
perature trigger
02
03
Setting number
Default
Default
Longer
Shorter
Enable
Disable
Display only on
central remote
control
Default
High Ceiling
Default
Raise
Default
Left half
Right half
SP mode 00
SP mode 01
SP mode 02
SP mode 03
SP mode 04
SP mode 05
SP mode 06
SP mode 07
SP mode 08
SP mode 09
SP mode 10
SP mode 11
SP mode 12
SP mode 13
SP mode 14
SP mode 15
SP mode 16
SP mode 17
SP mode 18
SP mode 19
SP mode 20
SP mode 21
SP mode 22
SP mode 23
SP mode 24
SP mode 25
SP mode 26
SP mode 27
SP mode 28
SP mode 29
SP mode 30
Normal SP
Default
Adjust (1)
Adjust (2)
Default
Adjust (1)
Adjust (2)
Adjust (3)
- (07 - 112) -
Adjust the filter cleaning interval notification. If the notification is too
early, change to setting 01. If the notification is too late, change to
setting 02.
Enable or disable the filter
indicator. Setting 02 is for use
with a central remote control.
Regulate the airflow according to the needs of the installation location.
When set to 01, the airflow will be stronger. (Cassette type only)
Adjust the vertical airflow direction. All airflow direction louvers are
adjusted together.
(Cassette type only)
Adjust the horizontal swing airflow direction.
(For horizontal swing equipped models)
Range of static
Model name
pressure mode
ARUL4TLAV1
SP mode 00 to 03
ARUL7TLAV
ARUL9TLAV
ARUL12TLAV
SP mode 00 to 09
ARUL14TLAV
ARUL18TLAV
ARUM24TLAV
SP mode 00 to 14
ARUM30TLAV
SP mode 00 to 11
ARUM36TLAV
SP mode 00 to 09
ARUH36TLAV
SP mode 02 to 16
ARUH72TLAV1
SP mode 05 to 30
ARUH96TLAV
SP mode 05 to 29
Refer to "7. FAN PERFORMANCE CURVE" in Chapter 4 for the
characteristics of each indoor unit.
Adjust the cool air trigger temperature. To lower the trigger
temperature, use setting 01. To raise the trigger temperature,
use setting 02.
Adjust the heat air trigger temperature. To lower the trigger
temperature by 6 degrees C, use setting 01. To lower the trigger
temperature by 4 degrees C, use setting 02. To raise the trigger
temperature, use setting 03.
Details
Normal static
pressure
0.04 in.WG
(10 Pa)
0.10 in.WG
(25 Pa)
0.16 in.WG
(40 Pa)
0.40 in.WG
(100 Pa)
0.60 in.WG
(150 Pa)