1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
• Example of phenomenon
The image on the trailing edge is tilted as shown below in the simplex mode.
Front side
Rear side
When this tilted image is printed in the duplex mode, image positions on the front and back sides
become as shown below.
• Adjustment method
e-STUDIO2010AC/2510AC
Loosen the 2 screws [2] on the fuser unit guide rail (front). Remove 1 screw [3].
Change its position to the adjustment hole [4] and move the fuser unit guide rail (front) [2] up or
down.
(Guideline of the movement: One scale)
• There is a 0.5 mm wide scale at the position indicated by [5].
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC