Toshiba e-STUDIO2010AC Imaging Manual page 51

Hide thumbs Also See for e-STUDIO2010AC:
Table of Contents

Advertisement

(5) Temporarily tighten the screw [9] removed in step (4)
into the screw hole [3].
(6) Select the closest value to the tilted volume "A-B" from the following table and check the scales of
the frame and the LSU holder to be aligned.
Front
Center
Rear
Remarks
© 2018 TOSHIBA TEC CORPORATION All rights reserved
1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
Scale position to be aligned
Frame
LSU holder
Eighth
Eighth
Seventh
Seventh
Sixth
Sixth
Fifth
Fifth
Fourth
Fourth
Third
Third
Second
Second
First
First
0
0
First
First
Second
Second
Third
Third
Fourth
Fourth
Fifth
Fifth
Sixth
Sixth
Seventh
Seventh
Eighth
Eighth
1-39
Tilted volume (A-B): [Unit: mm]
297 mm (A3)
1.12
0.98
0.84
0.7
0.56
0.42
0.28
0.14
0
-0.14
-0.28
-0.42
-0.56
-0.7
-0.84
-0.98
-1.12
Moving approx.
0.14 mm per 1
scale
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
279 mm (LD)
1.04
0.91
0.78
0.65
0.52
0.39
0.26
0.13
0
-0.13
-0.26
-0.39
-0.52
-0.65
-0.78
-0.91
-1.04
Moving approx.
0.13 mm per 1
scale