X500/X501 Drive-Cliq Interfaces; X520 Digital Inputs - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.4.2.2

X500/X501 DRIVE-CLiQ interfaces

Table 6-11
Connector
type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Note
The maximum DRIVE-CLiQ cable length is 100 m.
6.4.2.3

X520 digital inputs

Table 6-12
Type: Screw terminal 1 (Page 321)
DI: Digital input; M: Electronics ground; M1: reference potential
1)
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
X500/X501 DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
X520: Digital inputs
Terminal
Designation
1
DI 0
2
DI 1
3
DI 2
4
DI 3
5
M1
6
M
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground
Technical data
1)
Voltage: -3 ... +30 V
Electrical isolation: Yes
Reference potential: M1
Input characteristic acc. to IEC 61131-2, type 1
Input voltage (including ripple)
"1" signal: 15 ... 30 V
"0" signal: -3 ... +5 V
Input current
at 24 V DC: typ. 9 mA
at <0.5 mA: Signal "0" reliably detected
Input delay
for "0" → "1": typ. 50 µs max. 100 µs
For "1" → "0": typ. 130 µs/max. 150 µs
Terminal Modules
6.4 Terminal Module TM31
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents