Meaning Of The Leds - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.5.4

Meaning of the LEDs

Table 6-30
Meaning of the LEDs on the Terminal Module TM41
LED
Color
READY
-
Green
Orange
Red
Green/re
d
Green/
orange
or
Red/
orange
Z pulses
Red
Green
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Status
Off
The electronics power supply is missing or outside the per‐
missible tolerance range.
Continuous
The component is ready for operation. Cyclic DRIVE-CLiQ
light
communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
The LED is activated irrespective of whether the correspond‐
ing messages have been reconfigured.
Flashing
Firmware is being downloaded.
light 0.5 Hz
Flashing
Firmware download is complete. The system waits for POW‐
light 2 Hz
ER ON.
Flashing
Component recognition via LED is activated (parameter
light
p0154=1).
Note:
Both options depend on the LED status when component
recognition is activated.
Off
The zero mark was found and the system waits for the zero
mark output.
OR
The component is switched off.
Continuous
The zero mark has not been released, or the zero mark
light
search is running.
Continuous
The system stops at the zero mark.
light
Flashing
The zero mark is output at each virtual revolution.
light
Description, cause
Terminal Modules
6.5 Terminal Module TM41
Remedy
Correct and acknowl‐
edge the fault.
Carry out a POWER ON.
153

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents