9.11.6
Installation
①
Figure 9-54
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is bare,
unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm (53.1 lbf in).
9.11.7
Technical data
Table 9-41
6SL3055-0AA00-5KA
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Max. cable length
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
encoder
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
50 (1.96)
Contact surface
Hole drilling pattern for installation
Technical data
)
9.11 Sensor Module External SME125
Ø5,3 (0.21)
20
M5 / 6 Nm
(0.78)
Unit
Value
V
24 (20.4 ... 28.8)
DC
A
≤ 0.20
DC
A
≤ 0.30
DC
W
≤ 4.5
m
30
V
5
DC
A
0.35
DC
kHz
≤ 500
Encoder system connection
50 (1.96)
Ø5,3 (0.21)
M5 / 6 Nm
1
20
(0.78)
10
(0.39)
309