X500/X501 Drive-Cliq Interfaces; X521 Temperature Sensor Input - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.7.2.2

X500/X501 DRIVE-CLiQ interfaces

Table 6-48
Connector
type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Note
The maximum DRIVE-CLiQ cable length is 100 m.
6.7.2.3

X521 temperature sensor input

Table 6-49
X521: Temperature sensor input
Terminal
1
2
3
4
5
6
7
8
Type: Spring-loaded terminal 5 (Page 320)
Measuring current via temperature sensor connection: 2 mA
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
X500/X501: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
Function
Technical data
- Temp
Temperature sensor connection Pt1000 / KTY84-130 / PTC / bimetallic
switch with NC contact
+ Temp
for linear motor applications, connect the Pt1000 or KTY84-130 motor
temperature sensor here
- Temp
Temperature sensor connection Pt1000 / KTY84-130 / PTC / bimetallic
switch with NC contact
+ Temp
for linear motor applications, connect the PTC triple element 1 or bimetallic
switch here
- Temp
Temperature sensor connection Pt1000 / KTY84-130 / PTC / bimetallic
switch with NC contact
+ Temp
for linear motor applications, connect the PTC triple element 2 here
- Temp
Temperature sensor connection Pt1000 / KTY84-130 / PTC / bimetallic
switch with NC contact
+ Temp
for linear motor applications, connect the PTC triple element 3 here
Terminal Modules
6.7 Terminal Module TM120
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents