Terminal Modules
6.4 Terminal Module TM31
Note
An open input is interpreted as "low".
Note
If the 24 V supply is briefly interrupted, then the digital outputs are deactivated during this time.
6.4.2.11

X542 relay outputs

Table 6-20
X542: Relay outputs
Terminal
1
2
3
4
5
6
Type: Screw terminal 3 (Page 321)
Maximum switching frequency at full load: 6 rpm
DO: digital output, NO: normally-open contact, NC: normally-closed contact, COM: mid-position contact
1)
Depending on the parameterization and the supply voltage (P24) of the TM31
2)
138
Designation
Technical data
1)
DO 0.NC
Contact type: Two-way contact max. load current: 8 A
Max. switching voltage: 250 V
DO 0.COM
Max. switching capacity at 250 V
DO 0.NO
Max. switching capacity at 250 V
DO 1.NC
Max. switching capacity at 30 V
Required minimum current: 100 mA
DO 1.COM
Output delay: ≤ 20 ms
DO 1.NO
Overvoltage category: Class II according to IEC 61800-5-1
. 30 V
AC
DC
: 2000 VA (cos φ = 1)
AC
: 750 VA (cos φ = 0.4)
AC
: 240 W (resistive load)
DC
2)
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2