Encoder system connection
9.7 Sensor Module Cabinet-Mounted SMC40
Interface assignment
The DRIVE-CLiQ and encoder interfaces of channel 1 and channel 2 are logically completely
independently of one another and permanently assigned.
X520/1
EnDat 2.2 input
X520/2
EnDat 2.2 input
Connector X524 for the electronics power supply is used for both channels.
9.7.2.2

X500/1 and X500/2 DRIVE-CLiQ interfaces

Table 9-22
Connector
type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Note
The maximum DRIVE-CLiQ cable length is 30 m.
268
X500/1
DRIVE-CLiQ socket
channel 1
---
X500/1 and X500/2: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
Reserved, do not use
B
M (0 V)
DRIVE-CLiQ socket
X500/2
Left RDY LED
DRIVE-CLiQ socket
---
channel 1
channel 2
---
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
-
Electronics ground
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Right RDY LED
---
channel 2