Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Removal
1. First shift the mounting slide downwards at the lug to release the interlocking with the
mounting rail.
2. Swivel the component to the front and withdraw it upwards from the DIN rail.
Figure 9-11
9.5.7

Technical data

Table 9-12
Technical data
6SL3055-0AA00-5BA.
Electronics power supply
Voltage
Current (without encoder system)
Power loss
Max. Cable length
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated (f
SSI baud rate
2)
Max. encoder cable length
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Mounting slide
Mounting rail
Removing from a DIN mounting rail
Unit
V
DC
A
DC
W
m
V
DC
A
DC
) kHz
encoder
kBd
m
Encoder system connection
9.5 Sensor Module Cabinet-Mounted SMC20
Value
24 (20.4 ... 28.8)
≤ 0.2
≤ 4
30
5 V DC (with remote sense)
0.35
≤ 500
100 - 1000
3)
100
1)
249