9.8.2.3

Encoder system interface

Table 9-28
Encoder system interface SME20
9
8
1
12
7
10
2
11
6
3
5
4
Connector kit:
Measuring current via temperature sensor connection: 2 mA
Blanking cover for encoder system interface: Pöppelmann GmbH & Co. KG, Lohne,
Article number: GPN 300 F211
These connections do not have safe electrical separation!
1)
Accuracy of the temperature measurement (temperature sensor, including evaluation):
2)
- Pt1000: ±5 °C (Pt1000 tolerance class B acc. to DIN EN 60751)
- KTY: ±7 °C
- PTC: ±5 °C
Connecting cable: Article number 6FX8002-2CA88-....
3)
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, then it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Pin
Signal name
1
B*
2
P5
3
R
4
R*
5
A
6
A*
7
-Temp
1) 2)
8
B
9
+Temp
1) 2)
10
M
11
M
12
P5
12 pole, article number: 6FX2003-0SA12
Encoder system connection
9.8 Sensor Module External SME20
Technical data
Inverse incremental signal B
Encoder power supply
Reference signal R
Inverse reference signal R
Incremental signal A
Inverse incremental signal A
Temperature sensor connection
Pt1000 / KTY84-130 / PTC
Incremental signal B
Temperature sensor connection
Pt1000 / KTY84-130 / PTC
Ground for encoder power supply
Ground for encoder power supply
Encoder power supply
3)
3)
277