Terminal Modules
6.7 Terminal Module TM120
NOTICE
Damage when using a non-specified temperature sensor
If sensors other than those specified are connected, this may result in incorrect measured
values. Damage can result if overheating is not detected.
• Only connect temperature sensors that have been specified for operation with a TM120
NOTICE
Overheating of the motor through jumpering the temperature sensor connections
Jumpering of the temperature sensor connections "+ temp" and "- temp" results in incorrect
measurement results. Damage to the motor can result if the overheating is not detected.
• When using several temperature sensors, separately connect the individual sensors to
The table below shows the preferable assignment of the connecting terminal for the
temperature sensor input:
Table 6-50
Preferable assignment, X521 temperature sensor input
Signal name
Terminal
1FW6
1
Pt1000
1)
2
Pt1000
2)
3
PTC 130 °C
4
PTC 130 °C
5
PTC 150 °C
6
PTC 150 °C
7
8
Instead of a Pt1000 temperature sensor, a KTY temperature sensor can also be used (negative pole).
1)
Instead of a Pt1000 temperature sensor, a KTY temperature sensor can also be used (positive pole).
2)
The interconnection provided is a suggestion (software default setting). Which temperature
sensor is connected to which input can be freely configured.
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
180
Terminal Module.
"+ temp" and "- temp".
1FN3
(2x1FN3)
Pt1000
1)
Pt1000
2)
PTC 120 °C
PTC 120 °C
(2_Pt1000)
1)
(2_Pt1000)
2)
(2 PTC 120 °C)
(2 PTC 120 °C)
1FN1
Segment motor
4 segments
Pt1000
1 PTC 120 °C
1)
Pt1000
1 PTC 120 °C
2)
Bimetallic switch
2_PTC 120 °C
with NC contact
Bimetallic switch
2_PTC 120 °C
with NC contact
3_PTC 120 °C
3_PTC 120 °C
4 PTC 120 °C
4 PTC 120 °C
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Meaning
Pt1000
Pt1000
PTC triple element 1 or bi‐
metallic switch with NC
contact
PTC triple element 2
PTC triple element 3
Control Units and additional system components