Connector kit:
Measuring current via temperature sensor connection: 2 mA
Accuracy of the temperature measurement (temperature sensor, including evaluation):
1)
- Pt1000: ±5 °C (Pt1000 tolerance class B acc. to DIN EN 60751)
- KTY: ±7 °C
- PTC: ±5 °C
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
NOTICE
Overheating of the motor through jumpering the temperature sensor connections
Jumpering temperature sensor connections "+Temp" and "-Temp" results in incorrect
measurement results. Damage to the motor can result if overheating is not detected.
• When using several temperature sensors, separately connect the individual sensors to
9.11.3.4

X500 DRIVE-CLiQ interface

Table 9-40
Connector
type
Power consumption max. 0.30 A
The blanking cover for the DRIVE-CLiQ port to secure the degree of protection IP 67 is not included in the
scope of delivery.
Blanking covers (6 units), article number: 6SL3066-4CA01-0AA0
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Pin
Function
6+1-pole, article number: 6FX2003-0SU07
"+Temp" and "-Temp".
X500: DRIVE-CLiQ interface
Pin
1
2
3
4
5
6
7
8
A
B
DRIVE-CLiQ socket
Technical data
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Encoder system connection
9.11 Sensor Module External SME125
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground