Installation; Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

9.9.5

Installation

5,3 (0.21)
Contact surface
Figure 9-36
Drilling pattern for installing the SME20/SME25
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is bare,
unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm (53.1 lbf in).
9.9.6

Technical data

Table 9-32
Technical data
6SL3055-0AA00-5HA.
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Max. cable length
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
)
encoder
SSI/EnDat baud rate
Protective ground conductor connection
Weight
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
50 (1.97)
Unit
V
DC
A
DC
A
DC
W
m
V
DC
A
DC
kHz
kBd
At the housing with M4 screw
kg
9.9 Sensor Module External SME25
50 (1.97)
10 (0.39)
Ø5,3 (0.21)
M5 / 6 Nm
20 (0.79)
Value
24 (20.4 ... 28.8)
≤ 0.15
≤ 0.25
≤ 4
30
5
0.35
≤ 500
100
0.31
Encoder system connection
Ø5,3 (0.21)
M5 / 6 Nm
1
10 (0.39)
20 (0.79)
285