6.6 Terminal Module TM54F
6.6.2.11

X532 fail-safe digital inputs

Table 6-42
X532: Fail-safe digital inputs
Terminal
1
2
3
4
5
6
7
8
9
10
An F-DI consists of 1 digital input and a 2nd digital input where, in addition, the cathode of the optocoupler is fed-out.
F-DI 7 = terminals 1, 2 and 7
F-DI 8 = terminals 3, 4 and 8
F-DI 9 = terminals 5, 6 and 9
Type: Screw terminal 1 (Page 321)
DI: Digital input, F-DI: Fail-safe digital input
1)
Pure hardware delay
2)
Note
Execution of a test stop
The test stop of the F-DI 5 to F-DI 9 can only be performed if the F-DI is supplied from L2+.
Note
Ensuring the function of digital inputs
For the digital inputs DIx+ to function, the reference potential must be connected to input DIx-
in each case.
This is achieved by using one of the following measures:
1. Providing the ground reference of the digital inputs
2. A jumper between DIx- and terminal M1
168
Designation
1)
DI 14
F-DI 7
DI 15+
DI 16
F-DI 8
DI 17+
DI 18
F-DI 9
DI 19+
DI 15-
F-DI 7
DI 17-
F-DI 8
DI 19-
F-DI 9
M1
Technical data
Voltage: -3 ... +30 V DC
Electrical isolation: Yes
Reference potential: see terminals 7, 8, 9, 10
Input characteristic acc. to IEC 61131-2, type 1
Input voltage (including ripple)
"1" signal: 15 ... 30 V
"0" signal: -3 ... +5 V
Input current
at 24 V DC: typ. 3.2 mA
at <0.5 mA: Signal "0" reliably detected
Input delay:
2)
for "0" → "1": typ. 30 μs
for "1" → "0": typ. 60 µs
Switching frequency: max. 100 Hz
Reference potential for DI 15+
Reference potential for DI 17+
Reference potential for DI 19+
Reference potential for DI 14, DI 16 and DI 18