STEP 5: AEVT - Assign virtual tie line data for E-CCIS.
RT:
TK:
TYPE:
DESTINATION: Destination Number (Maximum 6 digits)
CALLING:
CALLED:
C_RT:
C_TK:
VRY:
OPR:
RA:
When Verification of Connection is in service, if the last four digits of the received number is not equal to
Note:
those of Called Number, the connection is not established.
STEP 6: AVTC - Assign Virtual Tie Line Number for the E-CCIS route.
STEP 7: ACBC - If required, assign Call by Call data for the E-CCIS route.
Route Number
Trunk Number
System type (Dch is used commonly or separately with ISDN trunk)
Calling Number (Maximum 24 digits)
Called Number (Maximum 24 digit s)
CCIS Signal Route Number
CCIS Signal Trunk Number
Verification of Connection
0: Not required
1: Required
Outgoing Route Selection Pattern Number of CBC Service
Order of Route Advance of CBC Service
NDA-24305