4. Programming
STEP 1: ASYD - Assign the following data.
STEP 2: Assign the numbering plan data for call origination.
STEP 3: ARTD - Assign the route data for Bch and Dch at each physical interface.
B-channel route data
CDN
15 (LSG)
28 (ANS)
30 (PAD)
31 (OGRL)
32 (ICRL)
34 (GUARD) =
45 (A/D)
49 (TRKS)
50 (DPLY)
65 (INT)
66 (DC)
113 (UUI)
118 (BOB)
Depending on the level diagram of the network. Data "4" is for standard.
Note 1:
Note 2:
Note that each office must be assigned a different value to avoid collision at the time of call origination.
TRKS=0 (When PRT/DCH is set as "User side" by DIP switch.)
TRKS=1 (When PRT/DCH is set as "Net side" by DIP switch.)
Assign "1" when the number display on LCD of terminal is required.
Note 3:
Assign "1" when the User-to-User signaling notification is required.
Note 4:
Assign "1" when the multi-rate bearer service is used.
Note 5:
IS-11572 (LAYER 3 SPECIFICATIONS FOR INTER-PBX SIGNALING PROTOCOL)
SYS-1 Index
186 bit6=1 (ISDN/CCIS is in service)
187=00 Hex
220 bit6=0 (ISDN is in service)
2 (ONSG)
=
2
4 (INSG)
=
2
5 (TF)
=
3
6 (TCL)
=
4
7 (L/T)
=
1
8 (RLP)
=
2
= 12
=
1
=
4
Note 1
=
1
=
1
1
=
1
= 0/1
Note 2
=
1
Note 3
= 10
= 15
=
1
Note 4
=
1
Note 5
PRT
PRT
Dip SW : User side
ARTD
: TRKS = 0
D-channel route data
CDN
2 (ONSG)
4 (INSG)
5 (TF)
6 (TCL)
7 (L/T)
15 (LSG)
30 (PAD)
31 (OGRL)
32 (ICRL)
34 (GUARD) =
45 (A/D)
65 (INT)
118 (BOB)
IS-11572
PRT
Dip SW : Net side
ARTD
: TRKS = 1
NDA-24305
=
2
=
2
=
3
=
4
=
1
= 13
=
7
=
1
=
1
1
=
1
= 10
=
1
Note 5