Motorola G24 Guide Developer's Manual page 511

At commands
Hide thumbs Also See for G24 Guide:
Table of Contents

Advertisement

Command Type
Set
Test
The following table shows the command modulation select codes.
Table 3-284: Command Modulation Select Codes - Modulation Parameters
<MOD> Value
24
48
72
96
Example
AT+FCLASS=1
OK
ATD035658584
CONNECT 19200
AT+FRH=3
OK
CONNECT 19200
AT+FTH=3
OK
(The terminal sends DATA. The G24 decodes and packs it into the HDLC frame and sends it to the remote
party)
CONNECT 19200 //G24 detected termination sequence <DLE><DTX>.
AT+FTM=?
+FTM: 24,48,72,96
OK
AT+FTM=96//Terminal selected mode 96
CONNECT 19200
(Terminal sends data stream encoded of the fax document)
OK //G24 detected termination sequence <DLE><DTX>.
December 31, 2007
Syntax
Response/Action
+FTM = <MOD>
OK
or:
+CME ERROR: <err>
+FTM=?
(list of supported
<MOD>s)
OK
or:
+CME ERROR: <err>
Modulation
TrainTime
Rec. V.27 ter
Rec. V.27 ter
Rec. V.29
Rec. V.29
AT Commands Reference Manual
Chapter 3: AT Commands Reference
Remarks
The Set command causes the G24 to
transmit data using the modulation
selected in <MOD>.
Rate (bit/s)
Required
2 400
4 800
7 200
9 600
3-427