Operation 2. TEACH Mode
(5) Manually move the joint that needs origin alignment to its approximate 0 pulse
52
position.
0 pulse position of Joint #1 : position aligned with X-axis in Manipulator coordinate
0 pulse position of Joint #2 : position where Arms #1 and #2 are in a straight line
0 pulse position of Joint #3 : upper limit position in motion range
0 pulse position of Joint #4 : position where the flat surface on the shaft faces toward
system
(Regardless of the Joint #1 direction)
0 pulse
Upper limit:
0 pulse
the tip of Arm #2
0 pulse
0 pulse
TP1 Rev.5