Asus DS300j G2 Series User Manual page 226

Disk array subsystems
Table of Contents

Advertisement

Controller was placed on reset during Fail
Over processing
Partner Controller was placed on reset during
Fail Over processing
Controller was reset as it was not able to join
the running partner controller
The controller has reset because it
encountered a firmware problem
Controller temperature is above the warning
threshold
The controller temperature is above controller
critical threshold
Controller temperature is within the normal
range
CRC
CRC error is detected while receiving CMD
information unit
CRC error is detected during Data Out phase
Disk Array
New disk array has been created
Disk array has been deleted
Disk array has been added
Disk array has been removed
Disk array settings have been changed
Disk array is transport ready
Drive Interface
Drive-interface controller is found
Drive-interface controller is NOT found
Drive-interface diagnostics has passed
Drive-interface diagnostics has failed
Drive-interface controller has generated a
general parity error
Drive-interface controller has generated a data
parity error
Enclosure
Enclosure temperature is above the threshold
Enclosure temperature is above the warning
threshold
Enclosure temperature is above the critical
threshold
Enclosure temperature is within the normal
range
220
No action is required.
Verify that the controller is running. If the condition
persists, replace the controller.
If resets happen frequently, update to new firmware or
replace the controller.
Check airflow around the ASUS DS300f G2. Check
blowers and fans.
No action is required.
If this message appears repeatedly, contact Tech
Support.
No action is required.
Remove physical drives in disk array and insert them
into a different subsystem. To cancel Transport Ready
Status, remove and reinsert the drives in their original
slots.
No action is required.
Restart the ASUS DS300f G2. If this message
appears repeatedly, contact Tech Support.
No action is required.
Restart the ASUS DS300f G2. If this message
appears repeatedly, contact Tech Support.
If this message appears repeatedly, contact Tech
Support.
Check blowers and fans.
Check airflow around the ASUS DS300f G2. Check
blowers and fans.
No action is required.
Shut down PSUs due to enclosure or
controller temperature over threshold
Event Log
Event logging is enabled
Event logging is disabled
Event log buffer is cleared in RAM
Event log buffer is cleared in NVRAM
Event log buffer is cleared in MDD
Fibre Channel
Fibre Channel controller has detected bus
reset
Fibre Channel controller has received a "LUN
reset" command.
Fibre Channel controller has encountered a
fatal error
Fibre Channel link is up
Fibre Channel link is down
Fibre Channel controller settings have
changed
Firmware Update
Firmware update is started
Firmware update is complete
Firmware update is fail
Back-end expander firmware upgrade is
started
Back-end expander firmware upgrade is
completed
Back-end expander firmware upgrade failed
Front-end expander firmware upgrade is
started
Front-end expander firmware upgrade is
completed
Front-end expander firmware upgrade failed
Host Interface
Host interface controller has detected bus
reset
Host interface controller has encountered an
unrecoverable error
Host interface controller has received an
"abort task" command.
Host interface controller has received an
"abort task set" command.
Host interface controller has received a "clear
ACA" command.
DS300f G2 Series User Manual
Shut down the ASUS DS300f G2
No action is required.
If this message appears repeatedly, contact Tech
Support.
No action is required.
Restart the ASUS DS300f G2. If this message
appears repeatedly, contact Tech Support.
No action is required.
No action is required.
Try the update again. If this message repeats, contact
Tech Support.
No action is required.
Try the update again. If this message repeats, contact
Tech Support.
No action is required.
Try the update again. If this message repeats, contact
Tech Support.
If this message appears repeatedly, contact Tech
Support.
Restart the ASUS DS300f G2. If this message
appears repeatedly, contact Tech Support.
No action is required.