Asus DS300j G2 Series User Manual page 228

Disk array subsystems
Table of Contents

Advertisement

Online capacity expansion has stopped
Online capacity expansion has encountered a
physical disk error
Online capacity expansion is aborted due to
an internal error.
Online capacity expansion is queued
Parity
Parity error is detected during Data Out phase If this message appears repeatedly, contact Tech
PDM
PDM is started
PDM is in progress
PDM is completed
PDM is paused
PDM is resumed
PDM is stopped
PDM is switched to rebuild.
PDM is stopped internally
Physical Disk (Physical Drive)
Physical disk is marked online
Physical disk is marked offline
Physical disk is marked as DEAD.
Physical disk has been reset
Physical disk assigned as global spare
Global Spare has been deleted
Physical Disk is no longer assigned as a
global spare
Physical disk assigned as dedicated spare
Dedicated Spare has been deleted
Physical Disk is no longer assigned as a
dedicated spare
Physical disk has been inserted
Physical disk has been removed
Command on physical disk has been re-tried
Physical disk ECC error is detected
Physical disk CRC error is detected
Bad sector is found on physical disk
Error is detected in remap sectors
Command times out on physical drive
Physical disk negotiation speed is decreased.
Previously configured disk is no longer found
222
If this action was not intentional, check the logical
drive's status.
Check the physical drive check table after OCE is
finished.
Reduce system load on the ASUS DS300f G2.
No action is required.
Support.
No action is required.
Resume PDM when ready.
No action is required.
If this action was not intentional, check the disk array's
status.
Replace the dead physical drive or reinstall the missing
drive.
The destination drive was removed or used for a
rebuild.
No action is required.
Replace the physical drive.
No action is required.
Insert the physical drive back into the system.
If this message appears repeatedly, replace the physical
drive
Replace the physical drive.
If this message appears repeatedly, replace the physical
drive.
Insert the physical drive back into the system.
A physical disk has encountered an unknown
(non-ECC) media error.
A physical disk has encountered PFA
condition
A configured dead physical drive has been
inserted
A physical drive page 0 settings have been
changed
A physical drive page 1 settings have been
changed (SATA drives)
A physical drive page 3 settings have been
changed (SAS drives)
Physical disk is marked as DEAD due to
removal
Physical disk is marked as DEAD due to
failure of reassign sectors command
Physical disk is marked as DEAD due to PFA
condition
Physical disk is marked as DEAD due to
forced offline state
Physical disk seen by partner controller not
seen here
Single ported physical disk seen by Partner
controller not seen here
Physical disk reported not ready
PSU (Power Supply Units)
PSU is not inserted
PSU is off
PSU is on
PSU is installed and turned on
PSU is functional and turned on
PSU is installed and turned off
PSU is functional and turned off
PSU is malfunctioning and turned on
PSU is malfunctioning and turned off
PSU has been removed
PSU 12V/5V/3.3V power is out of the threshold
range
PSU 12V/5V/3.3V power is within the normal
range
PSU is critical. This may cause ins tab ility of
the system
PSU Fans
PSU fan or blower has turned on
PSU fan or blower has turned off
PSU fan or blower speed is increased
PSU fan or blower speed is decreased
PSU fan or blower is malfunctioning
DS300f G2 Series User Manual
If this message appears repeatedly, replace the physical
drive.
Clear the PFA condition. If this message appears
repeatedly, replace the physical drive.
Replace the physical drive.
No action is required.
Replace the physical drive.
Check and correct SAS connections. Verify that SAS-
to-SATA adapters are installed on all SATA drives.
Install an SAS-to-SATA adapter on the SATA drive.
Replace the physical drive.
Reinstall the power supply unit.
Turn on the power supply or plug in the power cable.
No action is required.
Turn on the power supply or plug in the power cable.
Replace the power supply unit.
No action is required.
Check the power to the PSU. Verify that the correct
PSU is installed.
No action is required.
Replace the power supply.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f g2 seriesDs300 g2 series

Table of Contents