Asus DS300j G2 Series User Manual page 72

Disk array subsystems
Table of Contents

Advertisement

v
fru vPD I
IewInG
nformatIon
FRU VPD refers to Vital Product Data (VPD) information about Field Replaceable Units (FRU) in the enclosure.
The number and type of FRU depends on the subsystem model.
To view FRU VPD information:
To make Enclosure settings:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Enclosure and click the FRU VPD button.
Use this information when communicating with Technical Support and when ordering replacement units.
For contact information, see "Contacting Technical Support" on page <?>.
v
P
S
S
IewInG
ower
uPPly
tatuS
To view the status of the power supplies and the fans that cool those power supplies:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Enclosure and click the View button.
4. Scroll down to view the power supplies.
The screen displays the operational and fan status of the power supplies. If any status differs from
normal or the fan speed is below the Healthy Threshold value, a malfunction is indicated in the Status
column.
See "Replacing a Power Supply" on page <?>.
v
c
u
S
IewInG
oolInG
nIt
tatuS
To view the status of the cooling units:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Enclosure and click the View button.
66
4. Scroll down to view the Blowers.
The screen displays the status and speed of the cooling units. If blower speed is below the Healthy
Threshold, a malfunction is indicated in the Status column. See "Diagnosing an Enclosure Problem" on
page <?>.
v
t
S
S
IewInG
emPerature
enSor
tatuS
To view the status of the temperature sensors:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Enclosure and click the View button.
4. Scroll down to view the Temperature Sensors.
If any temperature exceeds the Healthy Threshold value, an overheat condition exists in the enclosure.
See "Making Enclosure Settings" and "Diagnosing an Enclosure Problem" on page <?>.
v
v
S
S
IewInG
oltaGe
enSor
tatuS
To view the status of the voltage sensors:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Enclosure and click the View button.
4. Scroll down to view the Voltage Sensors.
If any voltage is outside the Healthy Threshold values, a voltage malfunction in the enclosure is indicated
in the Status column. See "Diagnosing an Enclosure Problem" on page <?>.
DS300f G2 Series User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f g2 seriesDs300 g2 series

Table of Contents